Pig Viscera Collection Trough


Pig Viscera Collection Trough

In a pig plant, the Pig Viscera Collection Trough serves as a stainless collection point that receives process liquid and directs it to treatment, storage or further processing. The final build must match the actual product load, room layout and cleaning routine at site. The HT listing supplies reference data for the offered arrangement; those figures are reproduced below for comparison. For export quotations, confirm voltage, materials, guarding, spare parts and documentation before the purchase order is released.

Contact Us

Product Overview

In a pig plant, the Pig Viscera Collection Trough serves as a stainless collection point that receives process liquid and directs it to treatment, storage or further processing. The final build must match the actual product load, room layout and cleaning routine at site. The HT listing supplies reference data for the offered arrangement; those figures are reproduced below for comparison. For export quotations, confirm voltage, materials, guarding, spare parts and documentation before the purchase order is released.

Working Principle

Liquid drains into the sloped tank body rather than onto the floor. The outlet arrangement then carries it to the selected pump, vessel or waste line. Adjustable feet help establish the intended fall during installation. Operators need a clear stop‑and‑recovery routine for a jam, tool change or hygiene break.

Main Features

  • Sloped, drainable collection area

  • Wash‑down‑friendly construction

  • Adjustable installation height

  • Outlet position matched to the plant drain

  • Robust frame for daily service

  • Simple access for inspection

Technical Specifications

ParameterReference Value / Buyer Check
ModelHT‑P608
ApplicationWhich main used for collect pig red and white viscera for cleaning
Out size4000*800/600*800mm(L*W*H)
Deep200mm
Component and material1) Stainless steel square tube (38*38*2mm ) 2) Stainless steel table board(2mm) 3) Drain hole 4) Stainless steel adjustable foot
Quotation controlConfirm tank length, depth, outlet size, drain direction, floor level and whether blood is recovered as a by‑product or sent to effluent treatment.

Reference configuration transcribed and normalized from the cited HT product page; confirm the final quotation and approved drawing.

Application

The usual application is bleeding areas and wet‑process zones where controlled collection, drainage and cleaning access are required. It can be specified for a new line or adapted to a retrofit, provided that the existing supports, working heights, utilities and control signals are measured on site. Plants handling several pig sizes should state the full range rather than quoting only an average.

Application Case

Illustrative reference case-A regional pork processor planning for 120 pigs per hour places the pig viscera collection trough between the relevant upstream and downstream stations. Before fabrication, the project team freezes the interface drawing, utility points and operator access. The acceptance check covers dry running, representative‑load operation, emergency stops, cleaning access and a spare‑parts handover.

Advantages

  • 1. Fits into a defined process stage, which makes line balancing and internal linking easier.

  • 2. Project‑specific dimensions reduce awkward field modifications at installation.

  • 3. Service points and replaceable wear parts can be agreed before shipment.

  • 4. Hygiene and drainage requirements can be reviewed with the equipment layout.

  • 5. Reference source data remains visible instead of being converted into unsupported marketing claims.

Pig Viscera Collection Trough FAQ

  • What information is needed to quote the Pig Viscera Collection Trough?

    Confirm tank length, depth, outlet size, drain direction, floor level and whether blood is recovered as a by-product or sent to effluent treatment.
  • Can it be connected to an existing slaughter line?

    Usually yes, but a retrofit needs measured drawings. Share the rail or conveyor interface, floor levels, travel direction, available space, utilities and current control method before engineering starts.
  • Which spare parts should be ordered with the machine?

    Start with the normal wear and hygiene parts for this duty: bearings, seals, sensors, chains or belts, nozzles, blades, scrapers, pneumatic parts and electrical protection devices as applicable. The supplier should issue a model-specific list.
  • Are the published technical figures final?

    No. The table records reference information from the citedHTpage. Capacity, power, dimensions, material grade and utilities must be confirmed on the quotation and approved drawing.
  • How should the equipment be accepted after installation?

    Use a documented site-acceptance test covering alignment, guards, emergency stops, interlocks, dry running, representative load, cleaning access, leakage or drainage, operator training and delivery of manuals and spares.